Bentley OpenComms Designer Help

Automatic Connections

Open the Automatic Connection Dialog Box

  1. From the Modify/Delete section of the Copper Tab select the Connections Auto command.
  2. Select the central office from which you want to run the automatic connections command. Every identical complement pair inside a splice enclosure associated with the selected device is spliced together and sheaths connected. They temporarily highlight on the map to show what has been connected.

    For example, if pairs 1-6 are available on the left side and pairs 1-6 are available on the right side, the Auto Connect automatically pairs them together.